I'm trying to track down the reason that one of my holding tank level lights isn't coming on when it should. The 1/3, 2/3 and full wires all go into this thing. Does anyone know what it is/does?
(Edited)
Your liquid holding tanks have three (or four) level sensors – they basically just report that they have completed a circuit because they are in fluid.
Rather than every wire running back to a central display, instead they go to this sealed device. It has several resistors inside.
One wire comes out of it to the display.
The display receives a certain voltage that has been reduced from 12v by the resistors. Based upon how much it was reduced, the display shows 1/4, 1/2, 3/4 or whatever.
You can see three wires going in, but only a single wire coming out.
Sensor issues in the black tank are often related to the sensor being covered up in – stuff. Spray cleaning the inside can help clear it off.
Not answering your question about this device, but on my holding tanks the individual lights go on the fritz like that all the time and then start working again later. I‘ve been assuming it’s from crap settling on the sensors in the tank and then getting dislodged later when I drive around.
Actually I’ve pretty much stopped even looking at the holding tank fill gauges. I gauge by the toilet; when it starts making a bit of a bubble on flushing then I’ve got a day or two to go dump.
Water proof connector?
LED light?
Join iRV2 forum. indispensable resource