I have a 2015 artic fox truck camper with the on an 2500 LP generator on board. The generator only has 4 hours on it currently since 2015. Have a feeling that is a big reason why it won’t start.
Generator cranks strong but will not start. Any advice on things to look for, replace, check to get it started and working before our next trip?
If it’s sat for a while without starting the generator you most likely need to clean the carburetor
Do you have propane? Is the valve on?
You’ve only run it four hours in nine years.
Have you ever changed the oil and filter? My guess would be change the oil.
After that if it’s still not working, your problem could be the carburetor as someone mentioned. After changing the oil try running “mechanic in a bottle” through. It might save you the step of having to clean the carb. Otherwise you gotta remove and clean the carb.
Check the air intake /exhaust does not have mice or wasps nests inside it.
I had trouble starting mine with one hour on it. The propane regulator in my camper was too small. Can’t recall speciations. But I had to get one with twice the flow rate and it worked flawlessly afterwards
Sweet camper you got