Stupid question, but I assume you have propane, correct?
This is a shot in the dark but it happened to me. Check the sail switch on the blower motor itself. Mine had hair stuck to it which was cause it to keep flipping while trying to start so my furnace would fire up and sh off immediately while still blowing air.
So this happened to me before. And it seems so silly now. But like.. light everything else. Turn your stove on. Light it. Keep it on. Light the water heater. Get some propane through the lines. Could just have not ran in awhile and there’s no propane in the lines?
As a quick alternative, If you have plug in power a small portable heater/fan will heat your unit cheap and efficiently. It takes like 20 minutes and most have thermostats. Way cheaper and easier than running the propane heater -.
An often overlooked and super simple problem is the vents in the coach are blocked. Make sure you don’t have any bags or cargo blocking the vents. This can prevent enough air flow for the sail switch to allow it to ignite.
Bad flame sensor. You can pull it out and clean with steel wool or lightly sand it.
*****Ive tried youtubing and reading my manual to trouble shoot but unsuccessful so far.