Things I am sure you already know to check, but just to remind:
– that you have propane for the furnace
– that your propane is turned on
– the circuit breakers and fuses for the heating system are all turned on. A lot of times, the thermostat, air conditioner, and furnace are all on different circuits, and often on both 110 and 12 volt.
– As shown in the photo, the temp is about 75, and the system is set to turn on and maintain 70. You would need to turn the heat up or wait for the temperature to fall for the heat to turn on.
What is the furnace doing? Does the fan come on? Do you ever hear the flame light? A furnace has multiple checks it goes through before it goes fully operative. If any one fails, it wont stay lit.
The heat starts with propane.
Is your stove lighting? If not, it may be the propane.
Is it cold inside? If the temperature isn’t colder than the setting it may not kick in.
Sorry OP.
Does the Heat setting on this panel control a separate furnace unit on the floor, or an electric heat strip in the roof AC unit?
Since it says Coleman-Mach I’m guessing it’s a heat strip in the AC unit. That might have a separate fuse or circuit breaker, so I might check that.
Does your RV use LP for heat? If so, your heating unit might need cleaning or have a bad valve.
Mine doesn’t work right now and I don’t know that it’s ever been clean.
Turn on your propane bottle
If you just had your LP tanks filled be sure the valves are open if they are close them and re-open them since vacuum might be causing a safety valve in the tank to close. Next take the cover off your heater (outside) and see if the ignition is clicking. It will make an audible click when the thermostat demands heat. If it doesn’t click make sure your house batteries are charged or you plugged into AC.