Slim_Parker:

There are (were) no near-floor level AC power outlets in my MH. Plugging in space heaters was awkward, the available plugs were kitchen counter or dining bench.

I’d removed my roof A/C after it stopped working (never run your roof A/C off of a 100ft 15 amp extension cable btw), so the dedicated 20 amp breaker in the power panel was free.

I left the A/C wiring in place, since I’d installed a duplex receptactle near where the A/C unit had been, and using 12/2 wiring rated for 20 amp circuits I tied in a new 15 amp duplex receptacle that I installed near the floor just under the power distribution.

So now I have 20 amps right near the floor, convenient for plugging in a heater.

I did a deep dive into the standards for 20 amp circuits, and yes, you can install 15 amp receptacles on a 20 amp circuit, as long as there are 2 or more and you use 12/2 throughout. And one duplex receptacle counts as two. And 15 amp receptacles have a 20 amp passthrough capacity.

If you noticed that I installed the receptacle ground pin up, it’s for a couple of reasons. In the part of the world I grew up that was the standard and I still instinctively orient plugs that way, and also it’s actually recommended: if a metallic object, say a coin or bit of wire, falls from above into a partially-out plug, it’s more likely to be in contact with ground before it shorts to hot or neutral, whereas in the traditional orientation a short between hot and neutral is almost certain. Or something like that.

Slim_Parker:

The usual caveats apply. Electricity is dangerous and can cause fires. If you’re at all not sure of what you’re doing, find and/or pay someone competent to do it for you.

Slim_Parker:

I thought a bit more about this, and you could do the same thing even if the A/C was still operational. Just don’t plug in any heavy-draw appliances when you’re using (in particular, starting) the A/C. (edit – not sure if that would be up to code)

River-trader:

Somehow this doesn’t add up.. 18 amps on a 15 amp receptacle are you forgetting about the 80% rule. 80% continuous load. Why didn’t you just spend the extra $1.50 and get the 20 amp plug I’m confused so now the 15 amp receptacle is the weakest link in the circuit. Hopefully it’s in a UL enclosure and not backstabbed.. oh I know receptacle ground is on the top so the heat from the two contacts can rise making the receptacle run cooler I get it now. It all makes sense. ???? My bad I apologize.

Source: Class C mod – new power outlet from unused air conditioner breaker

How to Winterize Your RV eBook

FREE eBook...
'How to Winterize Your RV'

Your Guide for RV Winter Living & Storage.

Valuable Tips & Info help you prepare for cold weather. Includes winterization instructions for full-time or part-time winter RV living.

It's FREE and there's no obligation...
Download your copy today.

Thank You! You will be redirected to the eBook download page shortly... After you've had a read through, please let us know what you think about the 'How to Winterize Your RV' eBook.