The comments on these questions are always hilariously incorrect
AC power is delivered in phases. In this situation you would either be getting two of them (208V) or one of them split in two (“split phase” at 240V) where the neutral wire comes from the center of the transformer.
Regardless of the situation when you take one hot and the neutral it’s 120V.
The dogbone you have here is simply taking one of the hots, neutral and ground and wiring it to the “30A” side. The dogbone doesn’t have anything to limit the amount of current you can draw so 50A is still possible which could lead to problems if the cable you’re using isn’t sufficient and something bad happens. That being said your main breaker in the RV should trip if you try to draw more than 30 from loads in the RV.
The top plug has two 120V legs, a neutral and a ground. It passes neutral and ground but only one of those 120V legs to the other side.
Because it’s 240v only because it has two 120v legs.
This simply ignores one of the 12v legs (there’s a prong, but like my career it’s not really going anywhere).
The other one is connected to the hot side of the 30a.
So in effect instead of two 50a legs; you have a single 50a leg. Which is fine; the amp rating of a circuit like this is merely the maximum amount of current that circuit can safely handle. Your 30a RV will still only pull what it needs and is protected by its own 30a breaker.
A common myth is that there’s “50 amps worth of power” squirting out of that 50a connector. That’s not the case. There’s only voltage there; what makes current (amps) is the loads you put on it. What makes it 50 amp is merely that it can handle up to 50 amps worth of loads, sustained, across both legs. Think of it like the speedometer in your truck. It might go to 140; that doesn’t mean you have to go 140. It also doesn’t mean that you can’t take your truck on a highway with a 55mph speed limit. Of course you can; you’ll just (ideally) not exceed 55mph even though your truck is capable of more.
It’s pretty simple.
The ground and neutral in the 50 amp plug go directly to the 30 amp receptacle.
The 50 amp plug has two 120 volt connections… only one of them goes to the 30 amp receptacle.
If you’re 5, it’s magic.
It doesn’t. That’s a NMEA14-50P to NMEATT-30R. It is 110/120V 50A to 30A, not 220V.
Source: Explain to me like i’m 5 as to how this turns 50amp 220v to 30amp 110 volt. Please and ty!