Hi all!
I'm reaching out to some of you experts on what to do here. Last night I left the gray tank open while the wife was in the shower. We had a typical Florida surprise downpour so I ran outside, slammed the gray push rod in a little too quickly and ended up bending the rod itself… at least it is stuck in the open position so we can continue to use the gray water. I've googled it, obviously I can't repair it until I get home, no biggie. My concern and question is if it is okay to drain the black with the gray tank open. I've got a great slope and the hose/drain is completely unrestricted. I understand the risk of cross contamination, but is it likely? I'm just not sure what the right move is. What would you do? I've attached a picture to show the slope I'm working with, and yes I used a palm frawn to make a P trap so the sewer gas isn't getting back to the tank.
TL:DR – Can't close gray tank, is it okay to drain the black with the gray tank still open?
Fort wilderness…. Now to read the issue and edit.
Edit: I would suggest running the grey while the black empties so that it pushes any black water down the chute as opposed to letting it transfer over to the grey.
Also, if you are inclined, you can order a replacement on Amazon and have it delivered to fort wilderness campground. They will hold it at the front desk for ya. It’s an additional 8 or 10 dollar fee thou……. Did it last time for a toilet seal.
Yea it’s fine. A pain in the ass to fix. I had to do one years ago. If you got the money it’s worth it to get a pro to do it lol. Just cap the clean out port when driving. It won’t hurt anything. And the black water will flow down hill and won’t affect the great water tank. Run the show will draining the black tank if your overly concerned.
Just because I’m curious and not trying to be rude at all, but why did you close the grey tank when it rained?
These are not hare to replace at all. A 7/16″ open end wrench, a catch tub/basin and a new gate valve and approx. 20/30 minutes. 4 bolts, gently spread the pipes holding the valve. remove valve, replace valve, tighten/sung up 4 bolts and you’re done!
Just have to verify if you need just the gate valve, or a gate valve with the bayonets for the plug cap….
I do both all the time, not a problem
during dumping I always have both valves open.
First black – when that is just drippled, I open the gray – with the black still open to flush out everything.
You can replace just the rod without doing the entire valve. That’s how I fixed mine. There’s a YouTube video I watched to learn to do it.
The most difficult part was cutting the under layer to access the set screw…and even that wasn’t too bad.
Source: Holding tank emergency…?