My 94 econoline has a hydroflame propane furnace that isn’t working. The fan will run but only blows cold. There is no clicking from the automatic ignition when the fan is running. I’ve tried jumping the snap disc to no avail. The sail switch is not accessible cause of how the furnace is mounted and would like to know if these symptoms are the culprit before I try to remove it. Or could it be the board? Any advice is appreciated, I’ve watched a few videos but not sure how to proceed.
You’ll have to dismount the furnace to access the sail switch, which is the most likely culprit.
If you know how that board works you can test for signal from the sail switch right at the board.
12v power goes to the thermostat then when the thermostat calls for heat the 12v goes to the high limit switch then the sail switch then to the board.
If the board sees 12v from the sail switch it will start the ignition sequence.
I always remove these and clean the fan cage, jets and any dust and hair while diagnosing the problem and I definitely recommend it gets removed and cleaned.
The sail switch is accessible but you have to remove the furnace to get to it.
I also recommend you remove the jet and clean it as well as they get little rust flakes plugging them up. I also check the igniter electrode and gap.
Good luck!
If you have the ability, take it apart, clean it, reassemble. It won’t spark if the gas flow is not proper.
You didn’t mention what model you have but check out the manual here: https://myrvworks.com/wp-content/uploads/2019/04/Atwood-Shop-Manual-HydroFlame.pdf
On page 16 it says:
As power is applied to the circuit board, the system does the following:
- A timing circuit allows the blower to purge the chamber (15-17 seconds)
- The board supplies current to the gas valve and causes it to open.
- As the valve opens, the board sends a high voltage spark to the electrode at the burner. The board detects the presence of a flame. If the flame is not sensed after approximately six seconds, the board will lock out (three try for ignition, one hour lockout and then three retry), shutting off power to the valve.
- If the system does not ignite and the thermostat
Step 2 seems to be where the furnace is failing so I would use a volt meter to see if the board is sending 12VDC to the valve.
If you don’t measure 12VDC then I would replace the board.
If you do measure 12VDC and the valve isn’t audibly opening I would replace the gas valve.
If none of what I said makes sense I would contact a mobile RV tech because you don’t want to mess with propane appliances if you can’t do basic troubleshooting.
There’s several failure points in these old Hydroflames. 17k btu right. Most likely the board. If I remember right you could put a Dinosaur UIB s or fan control board in it. I think I still have my old test board.
Not an expert but we had this issue before and it just needed to be cleaned out (lots of dust and dog hair).