I have a Furrion fact11ma-ps model unit in the bedroom in my RV and I have two questions.
-
Is it normal for this to blow almost on high when it’s on? Even when I turn the fan controller down from the high setting to low it doesn’t reduce the fan very much at all. Is this normal? It’s a 2023 model in my JAYCO WhiteHawk.
-
This unit does not have an automatic temp shutoff like my other unit, so how does the freezing sensor work if it detects the coils are starting to freeze. Will it automatically turn off at that point then kick on again. Thanks for the help
In many of the new AC units across brands they have learned that running on low ram speed increases the chance of freeze up because of the reduced air flow. However customer base still wants a low fan mode so they have now designed the units so the low mode is only about 100-200 rpm slower on the fan speed. It gives a sense of a low speed mode while still maintaining a high level of air flow to prevent freeze up. And yes there is a freeze sensor in the coils. In the event of a freeze up it will shut itself off, actually it only shuts off the compressor but leaves the fan running again to keep air moving and mitigate the freeze up
Source: Furrion A/C