Since rewiring our batteries to fit to our shunt and solar charge controller a couple weeks ago, I've noticed that both the starter(chasis) and house batteries mirror voltage. Setup is: 2x 12v Deep Cycle (1 sealed, one not), and 4x 6v Flooded Lead Acid (series parallel).
So far I haven't noticed anything bad. In fact, now we can use our battery boost (couldn't before) and don't have to manually shut off our 12v chassis system when parked for longer than a day (used to drop below 12v after 8 hours and couldn't start engine). I haven't had to worry about voltage or state of charge in weeks!
Is this too good to be true??
Do you have a battery isolator so that if the voltage drops below a certain point it will disconnect the chassis battery and you won’t drain both? Sounds like you’ve just wired them in together somehow and I would argue that’s not good unless you’ve got a way to automatically isolate the starter.
You, somehow, have both positive cables combined from both batteries. Either on the buss bar, charge controller or battery posts. You need to trace back the cables. It could be a bad battery shut off switch, which really isn’t disconnecting that battery.
Time to start with your multimeter and take some readings.
I have a similar condition that is caused by our battery isolation manager, when there is no ignition positive signal (engine running) it selectively ties the banks together to balance voltage based on each banks levels, to help with charging. It has a similar algorithm when it detects a signal from the ignition (engine on.)
It has caused no issues in the actual charging of my house bank to date, my shunt verifies I have matching amps entering just my house bank during the solar charge cycle.
The BIM will unlatch/untie the banks when it reaches a certain voltage.
More info on the topic: https://www.thorforums.com/forums/f10/chassis-coach-battery-voltages-25455.html
There are too many variables for anyone here to decisively answer this.
Are you certain your Victron SmartShunt is actually wired up correctly to both the Starter and House Batteries AND programmed correctly so you are certain you are not getting two readings of the same battery?
Like everyone else said, how are your Starter and House batteries connected? Automatic Isolator? Manual Switch? Just a big fused wire?
You need to make a schematic of your 12vdc systems. You have at least 3 charging sources.
- Engine Alternator
- Solar
- DC Converter/Charger
- Generator?
Your House and Starter batteries could be interconnected through any of the those devices. Without a complete diagram of your 12VDC system, we’re all just making guesses and so are you. Go diagram the whole system so you already have it done when something goes wrong. It’s a bit of work, but otherwise you are relying on luck.