Should indicate a blown fuse.
Is the fuse loose? The light is basically on whenever there’s a complete circuit present but no good fuse present simply by virtue of how the light is wired to parallel the circuit. If the fuse is good but the light is still on that would suggest that there is a high amount of resistance present at the fuse connection and some of the electrical current is taking a less resistive path through the light.
Forgot to mention; I have replaced the 7.5 fuse but the dim light remains. When fuse is pulled the light goes full bright.
Following out of curiosity
Is there anything not working? Could the identification circuit have failed?
With everything working I’d be tempted to leave it alone. But it looks like you have an empty fuse holder and terminal. You could put a new fuse in and move the wiring down to slot 11. Knowing if the symptoms follow, could help narrow the problem down.
You’ve got an incomplete connection in the circuit board, and the LED is indicating it’s receiving voltage when it shouldn’t be, as if the fuse were blown.
Pull the panel and check the soldered connections on the back of the board.
While it’s tempting to leave it alone with everything working, I urge you to pull and check it because a loose connection could cause sparks, a short, or worse.
Source: Not sure what this light on the panel is indicating.