Firstly, that looks bad, like has it ever been cleaned, clean equipment is happy equipment. if I was going to work on it I would first charge a $125 cleaning fee.
Code 3 is a generic fault for many other things. No fuel is one.
Is your fuel tank above 1/3 full – if not the generator won’t pickup fuel as the pickup is high in the tank, so you run out of generator fuel and can still drive to get fuel ( idiot proofed )
Code 3 can be LOW or HIGH oil also.
Clean the whole generator with some engine degreaser / wash it down and a service on the generator. New oil, air filter / fuel filter and spark plug. A full service kit is $75
Go to https://www.dinosaurelectronics.com/Onan_Chart.htm and match up your control board. If they have one for your model it’s WELL worth the cost and much more reliable.
Low oil?
I’d start troubleshooting with the easy ones. Oil level and fuel level.
Then I’d remove the fuel line from the bottom of the carb and prime the motor. If no fuel comes out you probably have a bad fuel pump. (Common on these).
If the fuel pump is ok, I’d replace the entire carb. They are pretty affordable on Amazon. I picked one up for mine for like 50 bucks. It bolts right on and takes about 20 minutes to swap out. My Onan 5500 was doing the same thing as yours and I ended up replacing the fuel pump and carb for about 80 dollars in parts. Been running perfectly ever since.
I replaced my carburetor and that fixed my problem. Had gotten gummed up. Spark plug, oil and air filter change also helped smooth out operation.
Look at your fuel lines, seeing the condition that unit is in they may be cracked causing a vacuum leak.
Pust the stop button. The 3 flashes only tells you there is a code. Count the flashes ther should be two sets like 2 then 7 would be a code 27. Look in your manual.
Try bi-passing the oil pressure switch.
Source: Onan Marquis 5500 generator starts and stalls immediately. Diag light flashes code 3.